2 . 1 . 3 O r d e r o f p r e c e d e n c e . ln the event of a conflict between the text of
this specification and the references cited herein, the text of this specifi-
cation shall take precedence .
REQUIREMENTS
3.
This specification makes provision for first
3.1 First article
testing.
article testing.
3.2 Selection of specifications and standards. Specifications and stand-
ards for necessary commodities services not specitied herein shall be
selected in accordance with MIL-STD-143 except as provided in 3.2.1 and 3.2.2.
Commercial parts having suitable properties may
3.2.1 Commercial parts.
be used where, o n t h e d a t e o f i n v i t a t i o n f o r b i d s , t h e r e a r e n o t s u i t a b l e
in any case, commercial utility parts, like screws, bolts,
standard parts.
nuts, and cotter pins, having suitable properties may be used provided:
They can be r e p l a c e b y s t a n d a r d p a r t s ( M S o r A N ) w i t h o u t a l t e r a t i o n .
a.
The corresponding standard part numbers a r e r e f e r e n c e d i n t h e p a r t s
b.
list and, i f p r a c t i c a l on the drawings
3.2.2 S t a n d a r d p a r t s .
With the exception in 3.2.1, MS and AN standard
p a r t s s h a l l b e used where thtey suit the purpose.
They shall be identified on
the drawings by the part number.
Materials.
3.3
Metals shall be of the corrosion-resistan type or suitably
3.3.1 Metals.
treated to resist corrosion due to fuels, salt spray, or atmospheric condition
likely to be met in storage or normal service. When materials are used in the
construction of the lift truck that are subject to corrosion, they shall be
protected against such corrosion in a manner that will in no way prevent
compliance with the performance requirements of this specification.
The use of
any protective coating that will crack, chip, or scale with age or extremes of
atmospheric conditions shall be avoided.
Unless suitably protected against electrolytic
3.3.2 Dissimilar metals.
corrion,dissimilar metals shall not be user in intimate contact with each
Dissimilar metal, are defined in MIL-STD-889
other
The design and construction of the type 1
3.4 Design and construction.
lift truck shall conform to drawing number 7447187.
The design and construc-
tion of the type 2 lift truck shall conform to drawing number 8141050.