3 . 9 R e l i a b i l i t y . The slings shall have a minimum Mean-Time-Between Failures
(MTBF) of not less than 120 cycles with a reliability of not less than 0.990 for a
one-cycle mission at 0.9 confidence.
3 10 Maintainability.
The slings shall be designed and constructed as
s p e c i f i e d herein to provide the following:
a. Minimum number of parts consistent with reliability and
performance specified herein.
b. Minimum amount of training and time necessary for assembly,
disassembly, location of trouble sources, and maintenance including
Where practical, parts and components shall be located or
servicing.
positioned for rapid and simple inspection and recognition of
e x c e s s i v e wear or potential failure.
c. Permit adjustments, servicing, replacement of parts and components
and other maintenance with minimum disturbance to other equipment parts or
or components. Parts and components shall be located for ample and rapid
access unless performance or reliability will be appreciably degraded by
t h e accessible location.
In performing maintenance, if engineering
reasoning or data determines that physical or visual interference between
items cannot be avoided, the item predicted to require the most
m a i n t e n a n c e shall be located for best accessibility.
d. Permit maintenance with general purpose tools and equipment normally
available commercially. Use of special purpose tools and equipment shall
be subject to approval of the procuring activity.
e. Minimum number of tools required for maintenance by design practices
such as reducing the variety of bolt head sizes to the practicable
minimum.
f . Foolproofness - Where improper Installation of an item could cause a
malfunction of the item or the equipment in which It is installed, an
unsymmetrical mounting means shall be provided where practical. That
mounting shall allow the item to be installed only in its proper operating
position.
If an unsymmetrical mounting means is not practical, the item
shall be so mounted that Its proper operating position can be readily and
visibly determined by service maintenance personnel.
3.11 Components.
The slings shall consist of the following major components:
Component Name
Requirement Para
Hoist attachment
3.12
Lifting attachment
3.13
Main body
3.14
Cable or strap clamps
3.15
Cable or strap terminals
3.16